Steam Boiler Technology & Efficiency | CERTUSS America

The inner workings of our steam boilers

Complete steam system in a container, fully configured at the factory, can be positioned flexibly

Type: quick steam generator

Just switch on! The CERTUSS quick steam generators react promptly. In no more than 5 minutes, the full steam output is ready in the water tube boilers. That's what we call efficient!

All advantages of CERTUSS original high-speed steam generators

Installation conditions

All models and sizes of CERTUSS steam boilers are approved by the EU to be installed in working rooms. Some of the sizes and models are even permit-free.

Safe operation: Installation also possible in workrooms

Multiple system with supply unit (CVE)
Simple operation via touch control

Efficiency

Optimum firing efficiency of 98 percent (with an economizer) saves money and meets the requirements for an environmentally friendly use of resources.

Innovative combustion air preheating and heat recovery

Glossary

CERTUSS high-speed steam generators briefly explained in our lexicon - from A as in ASME to W as in water tube boiler.

Glossary on the design of CERTUSS steam generators

CERTUSS stock

Energy-Saving And User-Friendly Steam Generation

LOW VOLUME, HIGH OUTPUT STEAM BOILER

  • Fastest available start to steam option, < 5 minutes
  • Space saving vertical design
  • Maximum operational safety, intrinsic to “pressure coil” pressure vessel design, and air-cooled shell
  • High performance and responsiveness to process steam requirements

THERMAL
EFFICIENCY

  • High energy efficiency with a standard thermal efficiency level up to 87% without an economizer
  • Air insulated shell results in minimal radiant heat losses – only warm to the touch at full operating capacity
  • Standard integral combustion air preheating boosts combustion efficiency

TOUCH SCREEN
CONTROL UNIT

  • Full color, multi-lingual
  • Easy to read, centralized monitoring and control
  • Local intranet remote screen mirroring functionality standard
  • Offsite remote screen mirroring via GSM, Ethernet, or WiFi (optional)
  • Operational messaging via text or email (optional)
  • Expanded monitoring outputs via PLC (optional)
  • Expanded monitoring and control inputs/outputs via BACnet, Modbus connectivity (optional)

Advantages

  • Quick start time of 3-5 minutes to reach full rated capacity
  • Standard thermal efficiency of up to 87% as a result of unique combined air insulation/combustion air pre-heating design
  • Significant space savings compared to vertical and horizontal tubeless/firetube designs
  • Maximum operational safety intrinsic to the design of the ASME stamped pressure coil minimizes risk to personnel and property
  • Fully automated, pre-programmable system operation via CERTUSS Thermotimat control – start up, shutdown, and blowdown
  • Optional automated short-term cold standby “preservation mode” for safe shutdown over weekends, or more
  • Reduction in field-labor costs for installation due to easy reassembly of pre-piped & pre-wired system components
  • Single-source, full steam boiler system solution, completely UL certified, and pre-commissioned prior to shipment
  • Fuel options include low pressure natural gas, propane, and #2 oil, as well as a dual fuel combination of natural gas/#2 oil (Universal TC)
  • Robust, all steel construction
  • Modular construction and quick steam production results in high performance system response from multiple boilers, as well as N+1 redundancy with less installed horsepower, and a smaller footprint.
  • High performance responsiveness to a wide range of steam demands
  • Minimal pressurized water maximizes personnel/property safety
  • Warm-to-the-touch air-cooled shell, even at maximum steaming capacity for increased personnel safety and lower ambient temperatures
  • Minimal and basic maintenance required, with spare parts available up to 20 years
  • Customer commitment, both from the factory and local representatives
  • 7” Full Color, Multi-lingual Touchscreen Display
  • Remote access optionally via Ethernet, Wifi or GSM
  • Operational and maintenance messaging capability optionally via email or text
  • Quiet, low vibration operation

The Functional Principle

By using the water tube boiler principle, the CERTUSS technology for generating steam offers maximum safety, reliability and instant availability of high quality steam.

  • The touch screen control panel simplifies operation and control of the boiler. All system configurations and settings of steam pressure are made here.
  • The pre-heated feed water is delivered to the boiler at approx. 195°F to 205°F. The heat frees the oxygen from water and reduces the risk of oxygen corrosion.
  • The boiler pressure coil is supplied with water through the feed water inlet. The change of phase from water to steam begins.
  • Two-stage integral burners provide precise pressure control, avoiding large swings due to purge cycles, and via full burner modulation.
  • When the steam has been produced, it leaves the generator through the steam outlet and is then ready for use.
  • Insulation material is made obsolete by guiding the combustion air from the top of the boiler through an outer shell, and from there into an inner, secondary shell, before delivering pre-heated air to the burner. This unique approach maximizes efficiency not only through increased combustion efficiency, by also by sharply minimizing radiant losses from a shell that remains only warm to the touch at maximum capacity.
  • The flue gas outlet connects to the chimney with or without an optional economizer.
  • Sediment is flushed out through the pressure coil blow-down valve. The safety relief valve opens automatically to discharge excess steam if the pressure is too high.

Unique Boiler Design

Unique air cooling of the outer jacket, which also serves to pre-heat combustion air, results in minimal radiant losses to ambient, and boosted combustion efficiency, resulting in 87% fuel-to-steam boiler efficiency, without the implementation of an optional flue gas economizer (by others). Optional Flue Gas Recirculation (FGR) contributes to reduced NOx.

CERTUSS boilers are all ASME stamped, and when purchased as a complete system, combining boiler, piping, wiring, and CVE accessory skid, provide the customer with UL certification not only for the boiler, but the entire system. Further, every CERTUSS system that leaves the factory has been fully pre-commissioned, testing and certifying the entire system before it arrives at the customer’s facility.

Informational
material

Full product overview

Interested in CERTUSS Steam?

Get connected with one of our local consultants and engineers to discuss your Steam project!